Isolator Synergy  - Electrode, electrosurgical, active, cardiac ablation, single-use Australia - English - Department of Health (Therapeutic Goods Administration)

isolator synergy - electrode, electrosurgical, active, cardiac ablation, single-use

aa-med pty ltd - 44661 - electrode, electrosurgical, active, cardiac ablation, single-use - the isolator is an electrosurgical instrument used for cardiac tissue ablation. when activated, the ablation and sensing unit generator delivers radiofrequency (rf) energy to the linear electrodes on the insulated jaws of the isolator. isolator devices are configured as vascular clamps and feature clamping jaws of various lengths. the isolator synergy clamps feature two pairs of opposing dual electrodes, an in-line handle with syringe-type actuation and button release mechanisms. it is intended to be used to create lesions within the heart to eliminate or reduce cardiac conduction and treat cardiac arrhythmia using radio frequency energy, supplied by a separate generator. it can be used during pulmonary vein isolation and atrial connecting lesions for the maze procedure for the treatment of cardiac arrhythmias including atrial fibrillation. it can also be used for lesions on soft tissue, such as the pulmonary vein.

Isolator Synergy Clamps - Lesion generator probe, radio-frequency Australia - English - Department of Health (Therapeutic Goods Administration)

isolator synergy clamps - lesion generator probe, radio-frequency

aa-med pty ltd - 32531 - radio-frequency ablation system probe, reusable - the clamps feature two pairs of opposing dual electrodes, an in-line handle with syringe-type actuation and button release mechanisms. when activated the sensing unit delivers radio frequency energy to the linear electrodes on the jaws of the isolator. the clamps have an attachment tip for which glidepath tape that is part of the device is attached. the glidepath tape instrument guide is used to facilitate the guidance of the instrument through the soft tissue. isolator synergy clamps are intended to ablate cardiac tissue during surgery.

CVRx Programmer System Model 9010 - Baroreceptor electrical stimulation system Australia - English - Department of Health (Therapeutic Goods Administration)

cvrx programmer system model 9010 - baroreceptor electrical stimulation system

aa-med pty ltd - 35369 - baroreceptor electrical stimulation system - the programmer system consists of programmer software, programmer interface, usb cord, power cord and computer. the software is installed on the computer to allow programming of parameters in the implantable pulse generator (ipg) and provide status indicators from the ipg. it also interrogates and can adjust the therapies being delivered by the ipg. the programming interface provides the telemetry interface to the ipg and is powered via the usb port on the computer. the programmer system is intended to allow noninvasive communication with the implantable pulse generator in barostim neo systems.the programmer system allows input of therapy parameters and retrieves information regarding the status of the implantable pulse generator. barostim neo system is indicated for patients with heart failure.

CVRx Barostim neo Carotid Sinus Lead Kit - Baroreceptor electrical stimulation system Australia - English - Department of Health (Therapeutic Goods Administration)

cvrx barostim neo carotid sinus lead kit - baroreceptor electrical stimulation system

aa-med pty ltd - 35369 - baroreceptor electrical stimulation system - the carotid sinus lead conducts the activation energy from an implantable pulse generator (ipg) to the baroreceptors located on either the left or right carotid sinus. the carotid sinus lead are available in two (2) lengths, model 1036 (40cm), model 1037 (50cm). both are supplied with a 2 mm electrode. these are fully interchangeable to allow for anatomical variations and to be used per the physician?s discretion. the barostim neo carotid sinus lead is a component of the barostim neo system, and is indicated for patients with heart failure. the kit consists of the carotid sinus lead, implant adapter and implant tool. the carotid sinus lead conducts the activation energy from the implantable pulse generator to the baroreceptors located on either the left or right carotid sinus.